Optical Fiber Conduite Filled Cable - OCFC

 

Application

 Outdoor cable

laying with air blown

laying with pulling Laying in

to the cable tray

Features

 Single-Layer, Stranded construction

(Up to 144 Fibers)

Nonmetallic construction Low weight High

tensile by Aramid yarns


 
  • Possibilities
  • Technical Specifications
  • Description
  • key words
  • User Comments

With glass yarn elements as rodent

protection Available with LSZH or other

jacket for flame retardant or any other

features Available with special Design

according to the customer request

Delivery length is as customer request.

 

CONSTRUCTION:

 

Specification

Recommended

Standard

IEC 794-1, ITU-T G652D, G655

Construction

Design Type

1-layer cable core /polyester tape /Aramid yarn as strength member/1jacket

Number of Fiber

12 … 72

Optical Fiber

Type

Single mode LWP, NZDSF

Color

1)white 2) red 3) Green 4) blue5) yellow6) black 7) brown 8)  

Central strength Member

Material

FRP

Diameter

Nom. 2.5 mm that will up coat to suitable diameter if required

Loose Tube

 

Tube Material

PBT

Filling Compound

Thixotropic jelly compound

Assembly

2-12 optical fibers will have placed loosely into a jelly-filled thermoplastic tube 

 

Diameter

Nom. 2.4 mm

Number of Fibers

2-12

Color

1)white 2) red 3) Green 4) blue5) yellow6) black 7) brown 8) violet 9) orange 10) pink 11) gray 12) natural

Stranding

2 to 12 loose tubes (and if necessary fillers) will be stranded around the strength member and will filled with jelly and wrapped with a layer of polyester tape. over the tape there are Aramid yarns as intermediate strength member

Core Wrapping

Polyester tape

Inner Sheath (Optional)

Material

….

Thickness

….

Armoring

None

Ripcord

2 opposite Ripcords under jacket

Reinforcement

Aramid yarns

Outer Sheath

Material

Polyethylene colored black

Thickness

Nom. 2 mm

Cable Diameter

Nom. 12.2…17.2 mm

Cable Weight

Nom. 0.107…0.209 kg/m

 

PERFORMANCE:

 

Specification

Recommended

Mechanical Characteristics

Tensile Strength

 

3 KN

Min. Bending Radius

Installation

15*D (Cable Diameter)

Operation

20*D (Cable Diameter)

Environmental Characteristics

Temperature

Installation

-30°C to +70 °C

Operation

-40°C to +80 °C

Performance Test

Compression

EIA/TIA 455-41-A

Pulling

IEC-794-1-E1

Water Penetration

FOTP-82

Kink

IEC-794-1-E10

Cable Flexing

EIA/TIA-455-104-A

Twist

EIA/TIA 455-85

Repeated Impact

EIA/TIA-455-25-C

Temperature Cycling

IEC-794-1-F1

Low or high temperature bend

EIA/TIA-455-37

 

 

Description

  Post a comment